Ranges and stoves

1962 Code SECTION 47-1243; 1952 Code SECTION 47-1243; 1942 Code SECTION 7511; 1932 Code SECTION 7511; Civ

No kitchen range or stove in any building shall be placed less than three feet from any woodwork or wooden lath and plaster partition, unless the woodwork or partition is properly protected by metal shields, in which case the distance shall be not less than eighteen inches. Metal shields shall be loosely attached, thus preserving an air space behind them. Hotel and restaurant ranges shall be provided with a metal hood, placed at least nine inches below any wooden lath and plaster or wooden ceiling, and have an individual pipe outlet connected with a good thick flue. The pipe shall be protected by at least one inch of asbestos covering or its equivalent.

Official source: South Carolina Legislature. Reproduced from public-domain South Carolina statutes; confirm against the official source for the current text. Not legal advice.